444 WIN-PAK User Guide
2 Enter a Name for the trigger. This name should
relate to its corresponding procedure.
3 Select a Procedure from the drop-down list.
Only user-defined procedures [as opposed to
system procedures] are displayed in this list.
4 Use the Trigger Source Type drop-down list to
select the type of trigger point being defined
[Input, Output, Reader, or Time Zone].
5 Click the All Sources check box if you want the
trigger to apply to all inputs, outputs, and read-
ers.
6 Select a Source SIO Board. Only the boards
configured for this panel are displayed in the list.
7 Once a Source SIO Board is selected, the Trigger
Source field is activated, allowing you to select
the exact point on the SIO Board that you want
to use as the trigger point.
8 In the Time Zone field, indicate the time zone
in which the trigger is active. This field defaults
to "Always On."