394 WIN-PAK User Guide
4 Pre Alarm Time is the amount of time that can
elapse after the door is opened, before a warning
[typically a beeping sound] indicates that the
alarm will be activated.
Using Held Open Time and Pre Alarm Time
Consider a door with a Held Open Time set at 30
seconds and a Pre Alarm Time also set at 30
seconds. As soon as the door opens, a beeping sound
is emitted (the Pre Alarm) indicating that an alarm is
imminent. At the end of the 30 second Held Open
Time, the alarm is activated.
Standard Reader Types
WIN-PAK is delivered with four standard reader types:
• Std NCI 5-Wire • Std HID
• Std Motorola • Std Mercury
Select any of these reader types to examine its
predefined configuration.
SIO Board Configuration – Inputs
Use the Inputs tab on the SIO Board Configuration
window (next illustration) to set up the input points
for the Reader Module.
Panel input points are configured using the Inputs
tab which lists all the input points available on the
current panel. Inputs are status points in the system
doors, windows, motion sensors, etc. Input points
can be linked to time zones, shunt time, as well as
interlocks.
Inputs that are added as ADVs are referred to as
monitor points within the system. Inputs that are
being used in conjunction with the door cannot be
added as ADVs.