430 WIN-PAK User Guide
Board selected first, followed by the Input/
Output selection made.
NOTE: If the point you need is not listed, make sure the
input point or output point is active (that the check box
next to the item is selected).
For example: if you choose a 2-Reader I/O board
with the Input radio button selected, the Point list
will contain all the input point ADVs that were set
up for the 2-reader SIO Board. Likewise, if you
select a 16-Relay Output SIO Board [and, of course
have the Output radio button selected], the Point list
will display all available output points for that board.
NOTE: The Point names displayed are those defaulted
by the system when the ADV is added.
6 Select the Alarm Action for the interlocked
point. The second point will take this action
when the initial input becomes active [alarm or
trouble].
Alarm and Normal Actions include:
• No Action
• Energize [turn the point on]
• De-Energize [turn the point off]
• Pulse On [energize the point for a
set amount of time]
• Pulse Off
7 Select the Normal Action for the interlocked
point. This is the action that the second point
will take when the initial input becomes inactive
[normal].