4 Select an Action from the list (e.g. Server
OK, or Server Trouble). This list varies
depending on the type of device being
configured. Refer to the "ADV Action
Groups" section of this chapter for examples.
Each action [Alarm, Normal, Trouble etc]
requires a priority setting to be viewed in the
Alarm monitor.
5 Set the Priority you want assigned to the
selected Action. If the priority is 0, the
action state will not be displayed in the
Alarm monitor, Control Map or Floor Plan
view. [1 is the highest priority, 99 is the
lowest.]
6 Select the Time Zone during which you
want the Action Group activated. The
default setting is Always, meaning the de-
fined actions take effect regardless of the
time.
7 Select the Write to History option if you
want the event written to the history file.
8 Select the Print option is you want this event
printed on the alarm printer.
9 Select any Command Files you want
activated in response to the selected Action.
A command file must be created to perform
the CCTV camera/monitor switching.
10 If a Sound File is to be activated in response
to the Action, it is selected here. Sounds will
only play if the event is displayed in the
Alarm View.
11 Insert the Message you want sent to the
Alarm Details window in response to the
Action.
Programming