Click Add in the ADV area (upper right) and enter
the necessary information. When the ADV is
completed, click OK to return to the panel dialogs
and complete the panel definition. The ADV name is
now assigned to the output.
Note: In the ADV definition, there are three states listed
for an output point: energized, de-energized, and trouble.
In the case of an output point, trouble means that WIN-
PAK cannot determine if the output is energized or de-
energized.
When an active output point is selected the
following options are available:
Time Zone: To turn an output point on during a
particular time zone, select that time zone from this
list.
First Valid Read Activates Time Zone: This
feature ensures that the Output does not turn on
at the beginning of the Time Zone but on the
first valid card used thereafter. At the end of the
Time Zone, the output will turn off
automatically (E.g. Snow day). Selecting a Time
Zone for the output enables this feature.
Pulse Time: Enter a value here (in seconds, minutes
or hours) to set the amount of time that the output
point is energized when triggered. This can be any
value from 0 to 63.
Interlocking: In the case of output points,
interlocking is linking the changing state of the
output to either an input, another output.
Enabling Interlocking for Outputs
1 Select an output from the output point Name:
list, and then select the Interlocking check box.
2 Select I or above the Point: option, to indicate
input point or output point respectively.
Programming