311
Reverse Read LEDs
Select this option to reverse the standard LED
operation of the reader. If this option is selected, a
reader that normally changes from green to red on a
valid card read, will change from red to green.
Split Time Zone
The Split Time Zone option is not available when
adding a PW-2000 panel.
Command File
Provides the name of the defined command files that
contain special programming for the control panel. A
command file must be defined before it can be
selected.
Initialization Command
The Initialization Command field displays the
command string sent to the panel at initialization,
based on the Advanced Options selected. Note that
as an option is selected or deselected, a
corresponding string in the Initialization Command
field is added or removed.
Site Codes
Enter up to 8 site codes in this section. Site codes
are encoded on cards, along with a card number, to
ensure that cards belong to the facility where access
is attempted. Click any space in the table to enter a
site code. If no site code is defined, then site code
checking is not performed.
NOTE: When the system is set up for 12-digit card
number (ABA card formats), Site Codes cannot be
entered.