American access system ADV-1000 Guía de usuario Pagina 264

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 777
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 263
264 WIN-PAK User Guide
8 Select the Port to which the loop is connected.
NOTE: Select the TCP/IP port only for N-485-PCI with
ACK/NAK enabled. It is not recommended to use
TCP/IP for other devices that do not use an ACK/NAK
protocol.
9 Enter the Bits per Second communication rate
for the loop. For optimum performance the 485/
PCI should be set for 19200 (19.2 K). This baud
ratemust match the 485/PCI’s baud setting.The
Data Bits, Parity, and Stop Bits fields default
based on the loop and port.
IP Address
If TCP/IP Connection is selected as the Port, the
IPAddress or Node name field must be filled in.
Encryption Password
If TCP/IP Encrypted Connection is selected as
the Port, the Encryption Password field must be
filled in with the exact [case sensitive] password
used when the LAN hardware was installed.
10 Create an ADV for the communication loop.
Click Add in the ADV section of the window
(upper right corner) to open the ADV window
for the loop.Follow the procedures outlined in
“Setting upADVs” (earlier in this chapter) to set
up the loop ADV.
11 Click OK to return to the Port Settings window.
The Loop becomes available on the Device Map.
Vista de pagina 263
1 2 ... 259 260 261 262 263 264 265 266 267 268 269 ... 776 777

Comentarios a estos manuales

Sin comentarios