Speedway Reader IPJ-R1000 for Gen 2 UHF RFID
36
Table 7-4 "config logging internallog" Command Parameters
Arguments Options Format Description
ApplicationLevel
<Emergency |
Alert |
Critical |
Error |
Warning |
Notice |
Info |
Debug>
STRING
Configures the level at and above which
ApplicationLevel logs are sent to the log
database. Listing in decreasing order of
severity.
ConfigurationLevel … STRING …
MgmtLevel … STRING …
NetworkLevel … STRING …
RFIDParameters … STRING …
RFIDSingulation … STRING …
RFIDAccess … STRING …
System … STRING …
Usage for the config logging internallog set command is shown below:
Usage: config logging internallog set <className> <level>
<className> is (ApplicationLevel | ConfigurationLevel | MgmtLevel |
NetworkLevel | RFIDParmeters | RFIDSingulation | RFIDAccess | System)
<level> is (emergency|alert|critical|error|warning|notice|info|debug)
A sample command that sets the RFID Access logging is shown below:
> config logging internallog set RFIDAccess emergency
Status=0,'Success'
7.4.3.2. config logging syslog Commands
The config logging syslog menu provides the configuration interface for the syslog module on the reader. If all remote syslog
servers are removed the reader will begin to log in its internal memory.
Commands:
add - Add a server to the list of current syslog servers.
del - Delete a server from the list of current syslog servers.
delall- Delete all current servers.
level - Change the severity level of the messages to log via syslog.
reset - Removes all archived syslog messages.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None